!AMPLITUDE¶
Specifies the changes of time of the variables which provide the load conditions in the step.
!AMPLITUDE, NAME=<name> [, optional parameter]
VAL1, T1, VAL2, T2, VAL3, T3 ...
(up to four items in one line)
| Parameter | |
|---|---|
NAME |
Name (mandatory) |
DEFINITION |
Type (omissible) |
TIME |
Type of time (omissible) |
VALUE |
Type of value (omissible) |
INPUT |
External file name (omissible) |
| Parameter Name | Parameter Value | Contents |
|---|---|---|
NAME |
<name> | AMPLITUDE Name |
DEFINITION |
TABULAR |
Default (default only in current version) |
TIME |
STEP TIME |
Default (default only in current version) |
VALUE |
RELATIVE |
Relative value (default) |
ABSOLUTE |
Absolute value | |
INPUT |
<filename> | External file name (omissible), can also be use together with the 2nd line or later |
| Parameter Name | Attributions | Contents |
|---|---|---|
VAL1 |
R | Value at time T1 |
T1 |
R | Time T1 |
VAL2 |
R | Value at time T2 |
T2 |
R | Time T2 |
VAL3 |
R | Value at time T3 |
T3 |
R | Time T3 |