Skip to content

!AMPLITUDE

Specifies the changes of time of the variables which provide the load conditions in the step.

!AMPLITUDE, NAME=<name> [, optional parameter]
VAL1, T1, VAL2, T2, VAL3, T3 ...

(up to four items in one line)
Parameter
NAME Name (mandatory)
DEFINITION Type (omissible)
TIME Type of time (omissible)
VALUE Type of value (omissible)
INPUT External file name (omissible)
Parameter Name Parameter Value Contents
NAME <name> AMPLITUDE Name
DEFINITION TABULAR Default (default only in current version)
TIME STEP TIME Default (default only in current version)
VALUE RELATIVE Relative value (default)
ABSOLUTE Absolute value
INPUT <filename> External file name (omissible), can also be use together with the 2nd line or later
Parameter Name Attributions Contents
VAL1 R Value at time T1
T1 R Time T1
VAL2 R Value at time T2
T2 R Time T2
VAL3 R Value at time T3
T3 R Time T3