!HEAT¶
Definition of control data regarding calculation
Parameter¶
TIMEPOINTS = Time list name (specify with !TIME_POINTS, NAME)
BETA = Parameter defining time integration scheme
Default for steady calculation: 1.0 (Backward difference)
Default for unsteady calculation: 0.5 (Crank-Nicolson method)
** 2nd line or later **
| Parameter Name | Attributions | Contents |
|---|---|---|
| DT | R | Initial time increment ≦ 0: Steady calculation > 0: Unsteady calculation |
| ETIME | R | Unsteady calculation time (mandatory for unsteady calculation) |
| DTMIN | R | Minimum time increment ≦ 0: Fixed time increment > 0: Auto time increment |
| DELTMX | R | Allowable change in temperature |
| ITMAX | I | Maximum number of iterations of nonlinear calculation (Default: 20) |
| EPS | R | Convergence judgment value (Default: 1.0e-6) |
Example of Use¶
!HEAT
(No data) ----- Steady calculation
!HEAT
0.0 ----- Steady calculation
!HEAT
10.0, 3600.0 ----- Fixed time increment unsteady calculation
!HEAT
10.0, 3600.0, 1.0 ----- Auto time increment unsteady calculation
!HEAT
10.0, 3600.0, 1.0, 20.0 ----- Auto time increment unsteady calculation
Remarks¶
Only when performing auto time increment unsteady calculation, TIMEPOINTS parameter can be used to specify time points at which results and/or visualization files are output.