Skip to content

!EIGEN

Parameter settings of eigenvalue analysis

Parameter

N/A

** 2nd line or later **

(2nd line) NGET, LCZTOL, LCZMAX, SIGMA
Parameter Name Attributions Contents
NSET I No. of eigenvalue
LCZTOL R Allowance (Default: 1.0e-8)
LCZMAX I Max No. of iterations (Default: 60)
SIGMA R Shift value \(\sigma\) (Default: 0.01)

Example of Use

!EIGEN
3, 1.0e-10, 40, 0.01

SIGMA normally does not need to be changed from its default value of 0.01. However, it may be necessary to modify this value when performing a free-free eigenvalue analysis (i.e., an eigenvalue analysis without any constraint conditions).

If a free-free eigenvalue analysis is performed and a 0 Hz eigenvalue appears in the computed eigenvalue solutions, increasing SIGMA to a value larger than 0.01 (for example, 1.0) may resolve the issue.