!CONTACT_PARAM¶
Specify contact scan parameter set.
Parameter¶
| Parameter Name | Attribution | Contents |
|---|---|---|
| NAME | C | Contact scan parameter set name (required) |
** 2nd line **
Specify clearance values in in-surface directions.
| Parameter Name | Attribution | Contents |
|---|---|---|
| CLEARANCE | R | ordinary clearance (Default: 1e-2) |
| CLR_SAME_ELEM | R | clearance for already-in-contact elems (loosen to avoid moving too easily) (Default: 5e-3) |
| CLR_DIFFLPOS | R | clearance to be recognized as different position (loosen to avoid oscillation) (Default: 1e-2) |
| CLR_CAL_NORM | R | clearance used when calculating surface normal (Default: 1e-4) |
** 3rd line **
Specify clearance values in directions vertical to the surface.
| Parameter Name | Attribution | Contents |
|---|---|---|
| DISTCLR_INIT | R | dist clearance for initial scan (Default: 1e-2) |
| DISTCLR_FREE | R | dist clearance for free nodes (wait until little penetration to be judged as contact) (Default: -1e-6) |
| DISTCLR_NOCHECK | R | dist clearance for skipping distance check for nodes already in contact (big value to keep contact because contact-to-free is judged by tensile force) (Default: 1.0) |
| TENSILE_FORCE | R | tensile force to be judged as free node (Default: -1e-2) |
| BOX_EXP_RATE | R | expansion rate of the box used for contact scan (the smaller the faster, the bigger the safer) (Default: 1.05) |
Example of Use¶
With the same settings as the default settings